359 research outputs found

    Sex- and Age-Related Changes in Connexin 43 Expression in Normal Rat Bladder

    Get PDF
    Purpose Gap junctions are intercellular channels to facilitate electrical and metabolic communication between adjacent cells. Connexin 43 is the most predominant type of connexin expressed on rat detrusor muscle cells. We investigated the connexin 43 expressions in various age groups of either sex in normal rats. Methods Eighty Sprague-Dawley rats were used for analysis. Each group was quantified by 8 rats at 1 week, 2 weeks, 1 month, 3 months, and 6 months of age in either sex. In each animal, bladder was removed without any kind of intervention and fresh-frozen in liquid nitrogen. Total RNA extraction was done with easy-BLUE total RNA extraction kit. Reverse transcription polymerase chain reaction was done for connexin 43 and glyceraldehyde-3-phosphate dehydrogenase as an internal control using ImProm-II Reverse Transcription System. Results In female rats, no age-related change was detected in connexin 43 expressions. In male rats, connexin expression at 3 months of age showed significant decrease compared with 1 week, 2 weeks, and 6 months of age (P<0.05). When connexin expression at the same age in male and female were compared, only 3 months group in male showed significant decrease than the same age group in female. Conclusions Our data suggest that the expressions of connexin 43 mRNA in normal detrusor muscle cell showed age-related changes especially in male rats. Although it is difficult to interpret these findings at this stage, age should be considered as a possible compounding factor affecting connexin 43 expressions in male rats

    Secure Multi-Party Computation of Boolean Circuits with Applications to Privacy in On-Line Marketplaces

    Get PDF
    Protocols for generic secure multi-party computation (MPC) come in two forms: they either represent the function being computed as a boolean circuit, or as an arithmetic circuit over a large field. Either type of protocol can be used for any function, but the choice of which type of protocol to use can have a significant impact on efficiency. The magnitude of the effect, however, has never been quantified. With this in mind, we implement the MPC protocol of Goldreich, Micali, and Wigderson, which uses a boolean representation and is secure against a semi-honest adversary corrupting any number of parties. We then consider applications of secure MPC in on-line marketplaces, where customers select resources advertised by providers and it is desired to ensure privacy to the extent possible. Problems here are more naturally formulated in terms of boolean circuits, and we study the performance of our MPC implementation relative to existing ones that use an arithmetic-circuit representation. Our protocol easily handles tens of customers/providers and thousands of resources, and outperforms existing implementations including FairplayMP, VIFF, and SEPIA

    Percutaneous radiofrequency ablation for hepatic tumors: factors affecting baseline impedance

    Get PDF
    PurposeWe aimed to evaluate factors that affect baseline impedance of percutaneous radiofrequency ablation.MethodsIn this retrospective study, we analyzed 51 patients with 55 hepatic tumors from November 2015 until April 2018. We measured the baseline impedance nine times with three adjustable tip sizes (2 cm, 2.5 cm, 3 cm) and three different pad locations (two pads attached on the thigh, four on the thigh, two on the back). The first roll-off time was measured with two grounding pads attached on the back. Body mass index, cirrhotic or non-cirrhotic liver parenchyma, previous procedure, tumor location, artificial ascites, active tip size, and the pad location were evaluated as potential factors affecting baseline impedance using the Mann–Whitney U test, t-test and analysis of variance test.ResultsComplete radiofrequency ablation was achieved in 51 patients. Body mass index (p = 0.897), cirrhotic or non-cirrhotic liver parenchyma (p = 0.767), previous procedure (p = 0.957), tumor location (p = 0.906), and artificial ascites (p = 0.882) did not significantly affect baseline impedance. Grounding pads located on the back showed the lowest baseline impedance (p < 0.001). Increase in active tip size showed gradual decrease in baseline impedance (p = 0.016).ConclusionThe factors affecting baseline impedance were the pad location and the tip size. Positioning pads on the back lowers the baseline impedance and can shorten the first roll-off time, ultimately resulting in reduced total ablation time

    Neuropsychological profiles of patients with obsessive-compulsive disorder: early onset versus late onset

    Get PDF
    In this study, we assess the neuropsychological profiles of both early and late symptom-onset obsessive-compulsive disorder (OCD) patients. The early and late-onset OCD patients are compared to the control group with a series of neuropsychological measurements. The late-onset OCD patients exhibited impaired performance on the immediate and the delayed recall conditions of the Rey-Osterrieth Complex Figure Test (RCFT) and the letter and category fluency of the Controlled Oral Word Association Test (COWA), compared to the normal controls and the early-onset OCD patients. The controls and early-onset OCD patients did not differ on any of the neuropsychological measurements taken in this study. These results suggest that different neurophysiological mechanisms are in play in early and late-onset OCD patients, and age of onset can serve as a potential marker for the subtyping of OCD
    corecore